Master Bilt MCR-33101 Installation & Operation Instructions page 29

Blast chiller
Hide thumbs Also See for MCR-33101:
Table of Contents

Advertisement

QUICK OPERATION GUIDE
The following operating statuses exist:
- The "off" status (the device is not powered)
- The "stand-by" status (the device is powered and is off)
- The "on" status (the device is powered, is on and is in stand-by for the start-up of an operating cycle)
- The "run" status (the device is powered, is on and an operating cycle is in progress).
If a power cut occurs during the "run" status, the device will operate as follows when this is restored:
- If a temperature-controlled blast chilling or deep freezing operation was in progress, these will be
started again from the beginning
- If a timed-controlled blast chilling or deep freezing operation was in progress, these will be started
again from the moment the power supply was cut-off
- If storage was in progress, this will be re-proposed.
1. Connect the device power supply, the device will
display the "MASTER-BILT" splash screen for 10
seconds, after which it will go to the "stand-by"
status.
2. Press and release the ON/STAND-BY key (1) and
then press the highest interactive key on the left (2)
to LOCK / UNLOCK the keyboard.
3. Press and release the ON/STAND-BY key (1) to
power up the display.
With the on status, the device will display the cabinet
temperature, real time and date. Real time and date
can be set in parameter settings.