Compressor Protection parameters
PAR
Description
C0
Minimum time between restoring power from power cut-off compressor
C1
Minimum time between two consecutive compressor switch-on
C2
Minimum time between compressor switch-off and switch-on
C3
Compressor switch on minimum time duration
C4
Duration Comp. switch-off cabinet storage probe error"Pr1" (C5, C9)
C5
Duration Comp. switch-on post blast chilling storage probe error"Pr1"
C6
Condensor Temp. above which the blocked condenser alarm "COH"
C7
Condenser Temp. above which block compressor alarm "CSd"
C8
Block compressor alarm delay
C9
Duration Comp. switch-on post deep freezing storage probe error"Pr1"
Defrost Parameters
PAR
Description
d0
Defrost interval (0 = no defrost)
Type of defrost:
0 = Electric defrost (fan off)
d1
1 = Hot Gas (fan off)
2 = Air (fan on)
3 = air with door open (fan on)
d2
Defrost termination Temperature (coil) (also see d3)
d3
Defrost Duration (0 = defrost will never activate)
d4
Defrost Start-up of blast chilling and deep freezing cycle (1 = yes)
d5
Defrosting delay on start-up
d7
Drip time duration
d15
Minimum duration of compressor switch-on activation of defrost
d16
Duration of pre-dripping
Temperature Alarm Parameters
PAR
Description
A1
Cabinet temp below setpoint which the minimum temp alarm activated
A2
Enabling of minimum temperature alarm
A4
Cabinet temp above setpoint which the maximum temp alarm activated
A5
Enabling of maximum temperature alarm
A7
Temperature alarm DELAY
A8
Maximum temperature alarm DELAY
A10
Duration power cut-off alarm memorized
AA
Duration buzzer activation on End blast chilling & deep freezing cycle
A11
Parameter A1 & A4 differential
A13
Memorization of Temp-Control blast chilling, deep freezing un-finish
A14
Reserved
46
Unit
Range
Min
0 – 240
Min
0 – 240
Min
0 – 240
Second
0 – 240
Min
0 – 240
Min
0 – 240
°C/°F
0 – 199
°C/°F
0 – 199
Min
0 – 15
Min
0 – 240
Unit
Range
Hrs
0 – 99
...
0 – 3
2/0
°C/°F
-99 – 99
Min
0 – 99
...
0, 1
Min
0 – 99
Min
0 – 15
Min
0 – 99
Min
0 – 99
Unit
Range
°C/°F
0 – 99
...
0, 1
°C/°F
0 – 99
...
0, 1
Min
0 – 240
Min
0 – 240
Min
0 – 240
Second
0 – 240
°C/°F
0 – 99
...
0, 1
...
...
ºC
ºF
1
1
2
2
1
1
0
0
10
10
10
10
80
176
90
194
5
5
30
30
ºC
ºF
12
12
2/0
7
45
30
30
1
1
0
0
2
2
0
0
0
0
ºC
ºF
10
10
1
1
10
10
1
1
20
20
20
20
5
5
3
3
2
2
1
1
...
...