A3 – Time-controlled blast chilling & storage
The time-controlled blast chilling and storage cycle is divided into the following two phases:
- Blast chilling
- Storage.
Operate as indicated to start the cycle:
1. Make sure the device is in the "on" HOME status.
2. Make sure that the keyboard is not locked and that no
procedure is in progress.
3. Press and release the key (1) and then press and
release the key (2): the device will display the blast
chilling duration and the work set-point during blast
chilling.
4. Press and release the MENU key and then press and
release the UP key or the DOWN key to select the
blast chilling duration and the work set-point during
blast chilling.
4.1 Press and release the key or the key to modify these
values and then the ESCAPE key to memorize them;
these values can also be memorized through
parameters r1 and r7.
5. Press and release the START/STOP key: the cycle
will be started.
During blast chilling the device displays the residual blast chilling time, the temperature of the cabinet,
the name of the program (if named) and the time passed from the start of blast chilling.
When the time expired for the blast chilling duration, the
device automatically passes to storage mode and the
buzzer is activated to indicate the time cycle has been
completed.
** The system can be stopped at any time during the cycle - press and release the START/STOP KEY