TECHNICAL SPECIFICATIONS

Technology:
Detection mode:
Detection range:
Angular resolution:
Min. detected object size (typ.):
Emission characteristics
IR laser:
Red visible laser:
Supply voltage:
Power consumption:
Peak current @ power-on:
Cable length:
Response time:
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
Input:
Max. contact voltage:
Voltage threshold:
Response time monitoring input:
LED signal:
Dimensions (D x W x H):
Material:
Color:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screen:
Norm conformity:
Specifications are subject to change without prior notice. All values measured in specific conditions.
75.5792.05 LZR-S600 20180814
75.5792.05 LZR-S600 20180814
laser scanner, time-of-flight measurement
motion and presence
Default: 33 ft x 33 ft @ 2% remission factor (max. 82 ft x 82 ft)
0.3516°
0.8 in @ 10 in
1.4 in @ 16 in
2.8 in @ 33 ft
6.9 in @ 82 ft
wavelength 905 nm; max. output pulse power 75 W (CLASS 1)
wavelength 650 nm; max. output CW power 3 mW (CLASS 3R)
10 – 35 VDC @ sensor side
< 5 W
1.8 A (max. 80 ms @ 35 V)
30 ft
typ. 20 ms (max. 80 ms)
+ output activation delay
2 electronic relays (galvanic-isolated – polarity-free)
35 VDC / 24 VAC
80 mA (resistive)
t
=5 ms; t
=5 ms
ON
OFF
typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic-isolated – polarity-free)
30 VDC (over-voltage protected)
Log. H: >8 VDC
Log. L: <3 VDC
< 5 ms
1 blue LED: power-on status
1 orange LED: error status
2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
5.0 in x 3.6 in x 2.75 in (mounting bracket + 0.55 in)
PC/ASA
Black
-45°, 0°, 45°
-5 – 5°
-3 – 3°
NEMA 4 / IP65
-22 – 140 °F if powered
0 – 95% non-condensing
< 2G
max. 30%, homogenous
2006/95/EC: LVD
2004/108/EC: EMC
2002/95/EC: RoHS
EN 60529:2001
-14 – 140 °F if unpowered
IEC 60825-1:2007
EN 60950-1:2005
EN 61000-6-2:2005
EN 61000-6-3:2006