13.3 Reflow Parameters

Laird surface mount modules are designed to be easily manufactured, including reflow soldering to a PCB.
Ultimately it is the responsibility of the customer to choose the appropriate solder paste and to ensure oven
temperatures during reflow meet the requirements of the solder paste. Laird's surface mount modules conform to J-
STD-020D1 standards for reflow temperatures.
Important: During reflow, modules should not be above 260° and not for more than 30 seconds.
Figure 13-22: Recommended Reflow Temperature
Temperatures should not exceed the minimums or maximums presented in
Table 18: Recommended Maximum and minimum temperatures
Specification
Temperature Inc./Dec. Rate (max)
Temperature Decrease rate (goal)
Soak Temp Increase rate (goal)
Flux Soak Period (Min)
Flux Soak Period (Max)
Flux Soak Temp (Min)
Flux Soak Temp (max)
Time Above Liquidous (max)
Time Above Liquidous (min)
Time In Target Reflow Range (goal)
Time At Absolute Peak (max)
Liquidous Temperature (SAC305)
Lower Target Reflow Temperature
Upper Target Reflow Temperature
Absolute Peak Temperature
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/bluetooth
Table
Value
Unit
1~3
°C / Sec
2-4
°C / Sec
.5 - 1
°C / Sec
70
Sec
120
Sec
150
°C
190
°C
70
Sec
50
Sec
30
Sec
5
Sec
218
°C
240
°C
250
°C
260
°C
31