Timing chart for alarm occurrence

In the torque mode and continuous operation to torque control mode, the forced stop deceleration function
cannot be used.
When the servo motor is at a stop due to an alarm or other factors, commands from the controller are not
accepted. When restarting the operation in the cyclic synchronous position mode, confirm the position
command.
When using the forced stop deceleration function
When [Pr. PA04.3 Forced stop deceleration function selection] is set to "2" (Forced stop deceleration function
enabled).
■Stopping with forced stop deceleration function
When an alarm is detected, the servo motor stops using forced stop deceleration and MBR and ALM are turned off.
Servo motor speed
0 r/min
Base circuit
ON
(Energy supply to
OFF
the servo motor)
Servo amplifier
display
MBR
ON
(Electromagnetic
OFF
brake interlock)
ON
ALM
(Malfunction)
OFF
*1 The model speed command is a speed command generated in the servo amplifier for forced stop deceleration of the servo motor.
Alarm occurrence
Commands from the controller are not accepted.
No alarm
(No alarm)
(Alarm)
Model speed command is 0,
and the speed is equal to or
less than zero speed
Alarm No.
*1
3 BASIC FUNCTION
89
3.10 Alarm function