List of auxiliary recording data

A list of auxiliary record data saved by the drive recorder is shown.
Instantaneous monitor data
The instantaneous monitor data is saved in the vicinity of the trigger condition establishment.
System configuration display data
The system configuration display data saved by the drive recorder is as follows. Incompatible items are indicated as [----].
Name
Servo amplifier identification information
Servo amplifier serial No.
Servo amplifier S/W No.
MAC address
IP address
Motor model
Motor ID
Motor serial No.
Encoder resolution
Accumulated power-on time [h]
Number of inrush relay on/off times [times]
LED display
Servo parameter
Servo parameters, such as those for the PA, PB, and PC groups, are saved in the drive recorder.
Outline
The identification information for the servo amplifier is displayed.
Indicates the serial number of the servo amplifier.
The servo amplifier software number is displayed.
Indicates the MAC address of the servo amplifier.
Indicates the IP address of the servo amplifier.
The model of the servo motor is displayed.
Indicates the servo motor ID.
Indicates the serial number of the servo motor.
The encoder resolution is displayed.
Indicates the accumulated power-on time on an hourly basis [h].
Indicates the number of inrush relay on/off times.
Indicates the contents of the servo amplifier display (LED).