COSMOS ChargeGuard EX: 10 Wire Instructions

The COSMOS ChargeGuard EX can be wired for either one time
access or for continuous access until disabled. Control wires for a
10 wire harness are Grey and Violet, as shown in Figure 16 and
Table 10.
NOTE: If an electric vehicle is connected when a
COSMOS ChargeGuard EX turns on after a power failure,
one charge session will be allowed to accommodate for
power outages.
Figure 16: COSMOS ChargeGuard EX Controls: 10 Wire
Table 10: COSMOS ChargeGuard EX Wiring: 10 Wire
ChargeGuard EX Wire
ChargeGuard Enable
External Activate
To enable COSMOS ChargeGuard EX, wire the Green ground wire
included in the 10-wire harness to the ChargeGuard EX Grey wire
as indicated Table 10 and shown in the Figure 17.
Figure 17: Enable COSMOS ChargeGuard EX: 10 Wire
HCS Optional Features User Manual
Color
Ungrounded
Grey
Standard operation
Violet
Charge not allowed
31
Grounded
ChargeGuard EX mode
Allows charging session