2.9 ~AAM

: Read the OEM module name.
Description
: ~AAM[chk](cr)
Syntax
~ is a delimiter character
AA=2-character HEX module address, from 00 to FF
[chk]=2-character checksum, if checksum disable
(cr)=0x0D
: valid command
Response
invalid command
no response
error or address error
! is a delimiter character indicating a valid command
? is a delimiter character indicating a invalid command
AA=2-character HEX module address
data=4-character for module name
[chk]=2-character checksum, if checksum disable
(cr)=0x0D
Example
:
command: ~01M(cr)
response : !0100007083(cr)
command: ~02M(cr)
response : !0200007083D(cr)
I-7083/7083D/7083B/7083BD User Manual (V 1.1, Dec/2007) ------------------ 33
!AA(data)[chk](cr)
?AA[chk](cr)
syntax error or communication
OEM module name of 01 is
00007083
OEM module name of 02 is
00007083D
no [chk]
no [chk]