Opening the
TP180 housing
(1)
(2)
(1)
(3)
(3)
IMPORTANT! Press the locking device on
(5)
the flat connector to unplug the earth lead.
Unplug the earth lead (5).
6
Remove the cover (6) and insulating
7
sheet (7).
Remove the two M5x18 TX25 screws
1
(1) on the control panel.
Swing the control panel (2) to one side.
2
Remove the four M5x18 TX25 screws
3
(3) on the front of the device.
83