No.
Name
CP.21
last error
CP.22
last error -1
CP.23
last error -2
CP.24
last error -3
CP.25
last error -4
CP.26
last error -5
CP.27
last error -6
CP.28
last error -7
Parameters CP.21...CP.28 display the last eight errors. With exception error "underpotential
E.UP" is not stored. The oldest error is displayed in CP.28. A new error is stored in CP.21.
All other errors are shifted to the next parameter. The oldest error (CP.28) is not applicable.
The meaning of the error messages is described in parameter CP.01.
No.
Name
CP.29
software version
Value range
0.00...9.99
No.
Name
CP.30
software date
Value range
0...6553.5
No.
Name
CP.32
puls off level
Value range
0.0...-1000.0 kW
No.
Name
CP.33
operating mode
This parameter determines the master or slave of regenerative units at parallel connection.
Further it is adjusted whether a harmonic filter or a commutation choke is series-connected.
Single units must be adjusted to master.
Value range
0
1
2
3
Meaning
Display of the inverter software version number (e.g. 1,11).
Meaning
Display of the inverter software date in the format „ddmm.y".
default
Meaning
If the adjusted regenerative power is decreased, the COM-
-0.8 kW
BIVERT R6-S switches the modulation off after turn-off de-
lay and changes into standby mode (display: „Stb").
Meaning
Master with commutation choke
Master with harmonic filter
Slave with commutation choke
Slave with harmonic filter
r/w
Enter
yes
r/w
Enter
Origin
In.24 set 0
In.24 set 1
In.24 set 2
In.24 set 3
In.24 set 4
In.24 set 5
In.24 set 6
In.24 set 7
r/w
Enter
r/w
Enter
Origin
cS.06
r/w
Enter
yes
yes
Origin
In.06
Origin
In.07
Origin
Pn.19
US - 43