Eizo ColorEdge PROMINENCE CG3146 User Manual page 63

Hdr reference monitor
Hide thumbs Also See for ColorEdge PROMINENCE CG3146:
Table of Contents

Advertisement

3.
Detach the back plate.
Remove the fixing screws on the plate, and detach the plate.
Attention
• The plate and screws must be removed, or the installation fixture may not be able to be positioned correctly.
• The removed plate and screws are not used to attach the installation fixture.
4.
Remove the screws from the four screw holes with 200 mm pitch.
Attention
• The screws removed in this step are not used to attach the installation fixture. Use separately sold,
commercially available screws.
5.
Insert commercially available screws into the four screw holes with 200 mm
pitch and fix the installation fixture in place.
Screws: M6 screws
Tightening torque: 2.0 N·m to 2.5 N·m
Attention
• Do not attach the installation fixture to the screw holes with 100 mm pitch. The monitor may be damaged,
which may result in injury or equipment damage.
Plate
Screw holes
100
Screw holes
200
Unit: mm
Unit: mm
Chapter 9 Reference