Eizo ColorEdge PROMINENCE CG3146 User Manual page 25

Hdr reference monitor
Hide thumbs Also See for ColorEdge PROMINENCE CG3146:
Table of Contents

Advertisement

Function
White
Temperature 4000 K to
Point
White(x) /
White(y)
Gamma
Gamma
(EOTF)
(EOTF)
Gamma
Policy
PQ Option
HLG System
Gamma
Settings
Set the White Point that will be used as a calibration target for
10000 K
SelfCalibration.
User
Set the White Point using the color coordinates (White(x) /
D50
White(y)) or color temperature.
D65
When specifying color coordinates, set the values for "White(x)"
D65 (CRT)
and "White(y)", respectively.
DCI-P3
When specifying the color temperature, set the color
temperature in units of 100 K or select a color temperature
0.2400 to
according to each standard.
0.4500
Note
• When color coordinates are specified, the color temperature
is changed to "User".
1.0 to 2.7
Set the gamma that will be used as a calibration target for
sRGB
SelfCalibration.
EBU(2.35)
Set the gamma, or select the gamma curve defined by each
L*
standard.
PQ
Note
HLG
• The "Gamma (EOTF)" becomes "Fixed" when adjusting with
Fixed
ColorNavigator 7.
Select the gamma adjustment method for SelfCalibration.
Standard
Gray Balance
• "Standard"
Fixed Gamma
Adjust the gray balance while retaining the contrast.
• "Gray Balance"
Adjust the monitor so that the chromaticity of the middle
tone area equals the white point.
• "Fixed Gamma"
Select to use specific gamma settings.
Attention
• If "HLG" is specified for "Gamma (EOTF)", "Fixed Gamma" is
selected and this setting cannot be changed.
• With "Gray Balance", all points of the grayscale are adjusted
toward the target white point. Select this to prioritize whiteness
when correcting the middle tone area. However, the following
restrictions apply when "Gray Balance" is selected:
- The contrast may decrease.
- The color gamut may be narrower than when adjusting with
"Fixed Gamma".
2
300cd/m
Set the PQ Option that will be used as a calibration target for
Clipping
SelfCalibration.
500cd/m
2
Note
Clipping
• This can be set when "PQ" is specified for "Gamma (EOTF)".
2
1000cd/m
Clipping
2
4000cd/m
Emulation
10000cd/m
2
Emulation
1.0 to 1.5
Set the HLG system gamma that will be used as a calibration
target for SelfCalibration.
Note
• This can be set when "HLG" is specified for "Gamma (EOTF)".
Description
Chapter 3 Advanced Adjustments/Settings
25