2nd Taught
Condition
Sensor positions
threshold midway
between taught conditions
Output OFF
Output ON
Darkest
Position
(no signal)
adjusted by
Manual Adjust
Figure 2. Two-Point TEACH (Light Operate
shown)
Bargraph
LED
Relative Contrast/
Number
Recommendation
6 to 8
Excellent: Very stable operation.
Good: Minor sensing variables will
4 to 5
not affect sensing reliability.
Low: Minor sensing variables will
2 to 3
affect sensing reliability.
Marginal: Consider an alternate
1
sensing scheme.
Push Button
• Press and Hold
Present Output ON
condition
• Click
Present Output
OFF condition
• Click
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
1st Taught
Condition
• Two-point TEACH
• Sets a single switching threshold
• Threshold is adjustable using "+" and "-" buttons (Manual Adjust)
Two-Point Static TEACH is the traditional setup method, used when two conditions
Most Light
(saturated
can be presented by the user. The sensor locates a single sensing threshold (the
signal)
switch point) midway between the two taught conditions, with the Output ON
condition on one side, and the Output OFF condition on the other (see Figure 2).
The first condition taught is the ON condition.The Output ON and OFF conditions can
be reversed by changing Light/Dark Operate status in SETUP mode.

Two-Point TEACH and Manual Adjust

Using Manual Adjust with Two-Point TEACH moves the switching threshold. The
lighted LED on the light bar will move to exhibit the relative amount of received signal.
Remote Line
No action required;
Power LED: OFF
sensor is ready for
Output LED: ON
1st TEACH condition.
Bargraph: #5 & 6 Flashing
• Present Output ON
condition
Power LED: OFF
• Single-pulse remote
Output LED: OFF
line
Bargraph: #5 & 6 Flashing
T
Teach Accepted
• Present Output OFF
Power LED: ON
condition
Bargraph: One LED flashes to show
• Single-pulse remote
line
Sensor returns to RUN mode
T
Teach Unacceptable
Power LED: OFF
Bargraph: #1, 3, 6, 8 flash to show fail
Sensor returns to "Learn Output ON"
condition
Minneapolis, MN U.S.A.
QS30 Series Diffuse-Mode Laser Sensor

Two-Point Static TEACH

Display Shows
relative contrast (good contrast
shown; see table above)
5
P/N 109027 rev. C

Hide quick links: