Remote Input; Teach Output 1 Switch Point - Banner R-GAGE Q130RA Series Instruction Manual

Table of Contents

Advertisement

®
R-GAGE
Q130RA Sensor

5 Remote Input

Use the remote input to program the sensor remotely.
The remote input provides limited programming options and is Active Low. Connect the gray input wire to ground (0 V dc),
with a remote switch connected between the wire and ground. Remote teach can also be performed using the button on
the Pro Converter Cable. The remote input wire is disabled by default. Pulse the remote input wire 10 times to enable the
feature. After enabling the remote input feature, pulse the remote input according to the diagram and the instructions
provided in this manual.
To use the Pro Converter Cable for remote input, click
the button on the cable. The Software cannot be sampling data while remote input is in use.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds.
Remote
Input
Note: If a factory reset is performed through the Banner Radar Configuration Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.

5.1 Teach Output 1 Switch Point

1. Pulse the remote input once. The green power LED flashes slowly.
2. Present the target.
3. Teach the Output 1 switch point.
12
Gray wire is remote teach input
Remote Teach
1x
Teach Output 1 Switch Point
1x
Remote Setup
2x
Output 1 Mode
1x
1x
2x
3x
4x
Sensitivity Selection
3x
Signal Strength Threshold = 1
1x
Signal Strength Threshold = 1.13
2x
Signal Strength Threshold = 1.25
3x
Signal Strength Threshold = 1.5
4x
Signal Strength Threshold = 2
5x
Signal Strength Threshold = 5
6x
Signal Strength Threshold = 6.5
7x
Signal Strength Threshold = 7.5
8x
Reset to Factory Defaults
8x
Enable/Disable Remote Teach
10x
Figure 6. Remote Input Map
www.bannerengineering.com - Tel: + 1 888 373 6767
Stop in the Banner Radar Configuration Software before pressing
Pulse Timing (T)
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Switch Point Object Teach (Normally Open)
Switch Point Object Teach (Normally Closed)
Switch Point Background Teach (Normally Open)
Switch Point Background Teach (Normally Closed)

Advertisement