Auto mode is intended for inexperienced operators and uses single pulse per wavelength. The
type of network to be tested must be specified.
• PON Type – Select from the following.
• Not a PON - Point-to-Point
• Manual PON – Point-to-MultiPoint (includes RFoG). Specify splitter type. (Connect
at Customer site.) Enables 1
be selected manually, if needed. For information on defining splitter loss values, see
Section 7.3.1.2 Splitter
• Auto PON - Point-to-MultiPoint where software will assign splitter types based on
event loss. (Connect at Customer site.)
• Auto PON to ONT: Ideal for fiber monitoring when connected at OLT site.
Recommend 50dB dynamic range.
OTDR Series e-Manual, RevE00
OTDR Setup: RXT-4113 Auto mode
st
Splitter and 2
Thresholds.
nd
Splitter fields so splitter settings can
Page 69 of 128