8.4.4 Additional zone
EPGA11~16DAV3 + EAVH16SU18+23DA6V
Daikin Altherma 3 H F
4P606487-1 – 2019.12
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat or external room
thermostat request setting (NOT in case of leaving water temperature setting).
Setpoint screen
Control the leaving water temperature for the additional zone via setpoint screen
[3] Additional zone.
See
"8.3.5 Setpoint
screen" [
Schedule
Indicates if the desired leaving water temperature is according to a schedule.
4
See
"8.4.3 Main
zone" [
#
Code
[3.1]
N/A
Heating schedule
Define a heating temperature schedule for the additional zone via [3.2] Heating
schedule.
See
"8.3.8 Schedule screen:
Cooling schedule
Define a cooling temperature schedule for the additional zone via [3.3] Cooling
schedule.
See
"8.3.8 Schedule screen:
Setpoint mode
The setpoint mode of the additional zone can be independently set from the
setpoint mode of the main zone.
4
See
"Setpoint
mode" [
#
Code
[3.4]
N/A
Heating WD curve
Set weather-dependent heating for the additional zone (if [3.4]=1 or 2):
4
107].
117].
Schedule:
▪
No
▪
Yes
4
Example" [
110].
4
Example" [
110].
118].
Setpoint mode:
▪
Fixed
▪
WD heating, fixed cooling
▪
Weather dependent
8
Configuration
|
Description
Description
Installer reference guide
127