Maintenance and service

11.7 About cleaning the water filter in case of trouble

11.7.1 To remove the water filter

Installer reference guide
184
1
3 Reconnect the pipe to the tank.
4 Reinstall the clip to fix the domestic hot water OUT pipe.
See also
2 7.2.3 To open the indoor unit [} 67]
INFORMATION
For yearly maintenance, you do not have to remove the water filter from the unit to
clean it. But in case of trouble with the water filter, you might have to remove it so
that you can thoroughly clean it. Then you need to do as follows:
"11.7.1 To remove the water
"11.7.2 To clean the water filter in case of
"11.7.3 To install the water
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
1 The water filter is located behind the switch box. To get access to it, see:
"7.2.3 To open the indoor
"7.2.4 To lower the switch box on the indoor
2 Close the stop valves of the water circuit.
3 Close the valve (if equipped) of the water circuit towards the expansion vessel.
4 Remove the cap on the bottom of the magnetic filter/dirt separator.