Daikin Altherma 3 H F Installer's Reference Manual page 208

Hide thumbs Also See for Altherma 3 H F:
Table of Contents

Advertisement

14
|
Technical data
Installer reference guide
208
NOTES:
1
Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN: green, YLW:
yellow, PNK: pink, ORG: orange.
2
This wiring diagram applies only to the outdoor unit.
3
When operating, do not short-circuit protective devices S1PH and S1PL
4
Refer to the combination table and the option manual for how to connect
the wiring to X6A, X4A and X41A.
5
Refer to the service manual for instructions on how to set the selector
switches (DS1). The factory setting of all switches is OFF.
(3) Legend
English
Legend
Field supply
Optional
Part n°
Description
A1P
A2P
A3P
A4P
BS1~BS4 (A1P)
C1~C4 (A1P, A2P)
DS1 (A1P)
E1H
E2H
E3H~E5H
F1U~F4U (A2P)
F6U (A1P)
H1P~H7P (A1P)
HAP (A1P)
K1R (A1P)
K1R (A4P)
K2R (A1P)
K2R (A4P)
K3R (A1P)
K4R (A1P)
K10R (A1P)
K11M (A1P)
Legend
Field supply
Optional
Part n°
Description
Printed circuit board (main)
Printed circuit board (noise filter)
Printed circuit board (leakage current)
Printed circuit board (ACS)
Push button switch
Capacitor
Dipswitch
Crankcase heater
Bottom plate heater (option)
Plate heat exchanger heaters
Fuse
Fuse (T 5.0 A / 250 V)
Light-emitting diode (service monitor is orange)
Light-emitting diode (service monitor is green)
Magnetic relay (Y1S)
Magnetic relay (E3H~E5H)
Magnetic relay (Y2S)
Magnetic relay (E2H)
Magnetic relay (Y3S)
Magnetic relay (E1H)
Magnetic relay
Magnetic contactor
Translation
EPGA11~16DAV3 + EAVH16SU18+23DA6V
Daikin Altherma 3 H F
4P606487-1 – 2019.12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents