Error code
Detailed error code Description
H9
00
HC
00
HC
01
HJ
10
HJ
11
J3
00
J5
00
J6
00
J6
07
J6
32
J6
33
J8
00
JA
00
JA
17
L1
00
L3
00
L4
00
L5
00
L8
00
L9
00
LC
00
P1
00
P3
00
OU: Malfunction of outdoor
air thermistor
Tank temperature sensor
problem
Second tank temperature
sensor problem
Water pressure sensor
abnormality
Boiler abnormality detection
OU: Malfunction of discharge
pipe thermistor
Malfunction of suction pipe
thermistor
OU: Malfunction of heat
exchanger thermistor
OU: Malfunction of heat
exchanger thermistor
Leaving water temperature
thermistor Abnormality
(outdoor unit))
Sensor communication error
Malfunction of refrigerant
liquid thermistor
OU: Malfunction of high
pressure sensor
Refrigerant pressure sensor
abnormality
Malfunction of INV PCB
OU: Electrical box
temperature rise problem
OU: Malfunction of inverter
radiating fin temperature
rise
OU: Inverter instantaneous
overcurrent (DC)
Malfunction triggered by a
thermal protection in the
inverter PCB
Prevention of compressor lock
Malfunction in communication
system of outdoor unit
Open-phase power supply
imbalance
Abnormal direct current t