Download Print this page

Cisco IE 5000 Product Documentation And Compliance Information page 4

Hide thumbs Also See for IE 5000:

Advertisement

In switch installations in a hazardous location, the DC power source could be located away from
Warning
the vicinity of the switch. Before performing any of the following procedures, locate the DC
circuit to ensure that the power is removed and cannot be turned on accidentally, or verify that
the area is nonhazardous before proceeding. Statement 1059
Warning
This equipment is supplied as "open type" equipment. It must be mounted within an enclosure
that is suitably designed for those specific environmental conditions that will be present and
appropriately designed to prevent personal injury resulting from accessibility to live parts. The
interior of the enclosure must be accessible only by the use of a tool.
The enclosure must meet IP 54 or NEMA type 4 minimum enclosure rating standards. Statement 1063
Warning
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature
outside the enclosure. Statement 1067
When used in a Class I, Division 2, hazardous location, this equipment must be mounted in a
Warning
suitable enclosure with a proper wiring method that complies with the governing electrical codes.
Statement 1069
Explosion Hazard—The area must be known to be nonhazardous before installing, servicing, or
Warning
replacing the unit. Statement 1082
This equipment has been tested by UL for the explosion, fire, shock and casualty hazards required by
Note
the applicable hazardous locations standards. UL certification does not cover the performance or
reliability of any GPS hardware, GPS operating software, or other GPS-related aspects of equipment
covered under this category. Accordingly, UL makes no representations, warranties or certifications
regarding the performance or reliability of any GPS-related functions of equipment covered under this
category.
Français
Les sections ci-après expliquent comment installer le commutateur. Pour plus d'informations, consultez
le Guide d'installation du commutateur Cisco IE 5000.
Pour obtenir des informations concernant l'installation du commutateur dans un environnement
Remarque
dangereux, consultez le chapitre
d'installation du commutateur Cisco IE 5000 sur Cisco.com.
Lorsqu'il est installé dans un environnement dangereux de Classe I, Division/Zone 2, cet équipement
Avertissement
doit être monté dans un boîtier certifié aux normes IP54 et ATEX au minimum.
La circulation de l'air autour du commutateur ne doit pas être entravée. Pour empêcher le commutateur
Avertissement
de surchauffer, vous devez respecter les dégagements minimaux suivants :
- En haut et en bas : 50,8 mm (2 pouces)
Product Documentation and Compliance for the Cisco IE 5000 Switches—
Documentation produit et conformité pour les commutateurs Cisco IE 5000
4
« Installation dans un environnement dangereux »
du Guide
78-100604-01

Advertisement

loading