Wiring the Power Source—Câblage de la source d'alimentation
English
Before you wire the power source, review the warnings in this section:
The input voltage range for the AC power module are 85 Vac and 264 Vac and 88 Vdc and 300 Vdc. For
Caution
the DC power module the range is 18 Vdc to 60 Vdc. Ensure input voltages fall within these ranges for
proper performance and safety.
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection.
Ensure that the protective device is rated not greater than:
AC: 5 A, DC: 15 A Statement 1005
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning
Only trained and qualified personnel should be allowed to install or replace this equipment.
Statement 1030
Hazardous voltage or energy may be present on power terminals. Always replace cover when
Warning
terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in
place. Statement 1086
Locate the AC and DC circuit breakers, turn them OFF, and tape them in the OFF position.
Step 1
Note
78-100604-01
Do not connect the switch to a power source that has an ON/OFF switch.