Table 4-15 Objects Related To The Trap Notification (When An Error Occurs) - Hitachi HF-W7500 40 Manual

Industrial computer, ras features
Table of Contents

Advertisement

(2) Objects related to the trap notification
Table 4-15 shows a list of the objects related to the trap notification when an error
occurs as well as a description and notification data for those objects. The enterprise
ID for the trap notification when an error occurs is as follows.
Enterprise ID:
iso.org.dod.internet.private.enterprises.Hitachi.systemAP.

Table 4-15 Objects Related to the Trap Notification (When an Error Occurs)

No.
Object
number
hfwFanError
1
hfwTempError
2
hfwSmartDetect
3
hfwHddOverRun
4
hfwMemError
5
hfwArrayError
6
No.1: %1 denotes the name of the failed fan.
Nos. 3 and 4: %2 denotes the drive bay number.
No.5: %3 denotes the name of the memory slot with frequent error correction.
No.6: %4 denotes the number of the array with an error. For this equipment, the array number is always 1.
hfwMibTrap.hfwRasErrorTrap
or
.1.3.6.1.4.1.116.7.45.1
Trap
Description
A fan failure occurs.
1
The temperature
inside the chassis
2
becomes abnormal.
A failure is
anticipated for the
drive.
3
The drive power-on
(=used) hours
exceeded the
4
threshold.
A frequent error
correction occurs.
6
A RAID error occurs. raidIndex
7
4. CHECKING THE HARDWARE STATUS
Object used
fanName
Name of the failed fan
fanStatus
2: Error
hfwFanStMsg
Revolution of %1 deteriorated remarkably.
tempName
Internal temperature
tempStatus
2: Error
hfwTempStMsg
Internal temperature exceeded prescribed
value.
hddIndex
The drive bay number of the drive
for which a failure is anticipated by SMART
hddStatus
3: Failure anticipated
hfwSmartStMsg
A failure may be imminent on the drive of
the drive bay%2.
hddIndex
The drive bay number of the drive for which
the power-on hours exceeded the threshold
hddStatus
5: Used hours exceeded the threshold.
hfwHddUseTimeStMsg
Used hours on the drive of the drive bay%2
exceeded prescribed value.
memName
Name of the memory slot with frequent error
correction
memStatus
2: Error (Frequent error correction)
hfwMemStMsg
In the %3, error correcting have occurred
with high frequency.
1
hfwArrayStMsg
An error occurred on Array%4.
4-33
Notification data
Value

Hide quick links: