4. CHECKING THE HARDWARE STATUS

4.5.2 Hardware conditions that can be acquired by using remote notification

The following hardware conditions and settings can be acquired from a remote device:
Fan condition
Temperature condition inside the chassis
Drive condition
Memory condition
RAID status (D Model only)
RAS function settings
Operational mode (normal mode)
Version information of the extended Management Information Base (MIB) for HF-W.
The following transitions of the hardware conditions are notified by using a trap.
(1) Fan condition
• Normal → Error
• Error → Normal
(2) Temperature condition inside the chassis
• Normal → Error
• Error → Normal
(3) Drive condition
• Normal → Failure anticipated
• Normal → Used hours exceeded the threshold
(4) Memory condition
• Normal → Frequent error correction
• Frequent error correction → Normal
(5) RAID status (D Model only)
• Optimal → Error (Degrade, Unknown, or Fail)
• Error (Degrade, Unknown, or Fail) → Optimal
(6) Operational mode
• HF-W stopped → Started in normal mode
• Running in normal mode → Running in simulation mode