Target Data - Mitsubishi Electric MELSEC iQ-R Series User Manual

System recorder user's manual (application)
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Target data

The following shows data used for the recording function.
Devices and labels that can be sampled
The following table shows the devices and labels that can be sampled by using the recording function.
Each device and label are sampled in 32-word units.
For the method for specifying a device and label to be sampled, refer to the following:
Page 26 Specifying a device and label to be sampled
■Devices that can be sampled
Device name (device)
User device
Input (X)
Output (Y)
Internal relay (M/#M)
Link relay (B)
Annunciator (F)
Link special relay
*2
(SB)
Edge relay (V/#V)
Timer (T/#T)
Retentive timer (ST/
#ST)
Long timer (LT/#LT)
Long retentive timer
(LST/#LST)
Counter (C/#C)
Long counter (LC/#LC)
Data register (D/#D)
Link register (W)
Link special register
*3
(SW)
Latch relay (L)
System device
Special relay (SM)
Special register (SD)
*3
File register
(R)
*3
(ZR)
Index register (Z, LZ)
Refresh data register (RD)
Module access device (Un\G)
1 FUNCTIONS
24
1.1 Recording Function
Number of
*1
points
*2
512
*2
512
*2
512
*2
512
*2
512
512
*2
512
32
32
8
8
32
32
*3
32
*3
32
32
*2
512
*2
512
*3
32
32
32
24
*3
32
*3
32
Size (word)
Remarks
32
When specifying a DX, an X is sampled.
32
When specifying a DY, a Y is sampled.
32
32
32
32
32
36
• When specifying a T, a contact (TS), coil (TC), and current
value (TN) are sampled.
• Even when specifying a TS, TC, or TN individually, all of
them are sampled.
36
• When specifying an ST, a contact (STS), coil (STC), and
current value (STN) are sampled.
• Even when specifying an STS, STC, or STN individually,
all of them are sampled.
32
• When specifying an LT, a contact (LTS), coil (LTC), and
current value (LTN) are sampled.
• Even when specifying an LTS, LTC, or LTN individually, all
of them are sampled.
32
• When specifying an LST, a contact (LSTS), coil (LSTC),
and current value (LSTN) are sampled.
• Even when specifying an LSTS, LSTC, or LSTN
individually, all of them are sampled.
36
• When specifying a C, a contact (CS), coil (CC), and
current value (CN) are sampled.
• Even when specifying a CS, CC, or CN individually, all of
them are sampled.
68
• When specifying an LC, a contact (LCS), coil (LCC), and
current value (LCN) are sampled.
• Even when specifying an LCS, LCC, or LCN individually,
all of them are sampled.
32
32
32
32
32
32
32
32
24
• Even when specifying a Z or LZ individually, all of them are
sampled.
• A Z or LZ is sampled in 24-word units even when
specifying it individually.
32
32

Advertisement