Ref / Pt.No: 294130
Revision: C
Date: 24-Mar-17
41
info
LIQUID_FILLING
42
info
ARM_MILKING
_TIMEOUT
43
info
ARM_ASSIST
_TIMEOUT
44
info
ARM_FINDUDDE
R_ERR
45
info
ARM_FINDTEAT
S_ERR
294130
Operating Instructions for Safe Use
Fullwood M²erlin
is the number of emptying
attempts after eating time has
elapsed).
The filling of the liquid doesn't
finish in time. Problems with
liquid supply or a problem with
the weighing platform.
Timeout during milking on arm
control box.
Timeout on arm control box
waiting for assistance.
Error on arm control box udder
cannot be found.
Error on arm control teats
cannot be found, (arm control
box has seen front teats).
No Data
Not used by M2.
No Data
No Data
Cow will be released,
Timeout manual
info message will be
assistance has passed.
generated and
system will continue
milking cows.
Cow will be released,
No teats can be found.
info message will be
generated and
After certain number of
system will continue
retries finding teats
milking cows.
system decides to stop.
After 3 fails in a row,
This alarm/warning is
system will generate
also raised when a cow
an error and will stop
is set to feeding only in
milking cows.
Crystal.
Cow will be released,
Not all teats can be
info message will be
found.
generated and
system will continue
After certain number of
milking cows.
retries finding teats
system decides to stop.
After 3 fails in a row,
This alarm/warning is
system will generate
also raised when a cow
an error and will stop
is set to feeding only in
milking cows.
Crystal.
No Data
No Data
No Data
1) Check laser glass /
clean laser glass /
exchange laser.
2) Check cow
follower/arm positioning.
1) Check laser glass /
clean laser glass /
exchange laser.
2) Check cow
follower/arm positioning.
Page 68 of 81