Operating Mode - Elesa MPI-15 Operating Instructions Manual

Magnetic length and angle measuring system
Table of Contents

Advertisement

Available languages

Available languages

Magnetic length and angle measuring system MPI-15
4. Keys' function
Programming
Select value
Select incremental
mode or absolute mode

5. Operating mode

5.1 Commissioning
Use the
key to switch on / off the system.
5.2 Absolute mode / incremental mode selection
Press the
key to switch from absolute mode to incremental
mode and vice versa. The selected mode is indicated on the display
by the symbols:
ABS - absolute
◀◀◀
- incremental
When the incremental mode (
counter is automatically set to zero.
5.3 Unit of measure selection
If parameter unitS is enabled ( EnAbLE ), the unit of measure
is selected by pressing the
the following: mm (0.1), inch (0.001), degrees (0.01), degrees (0.1),
degrees (1).
If parameter unitS is disabled ( diSAbLE ), the unit of
measure cannot be changed in the operating mode.
5.4 Direct loading of the absolute reference value
If parameter LoAdOrG is enabled ( EnAbLE ) and the absolute
mode is selected ( ABS ), the reference value is directly loaded by
pressing the
key.
If parameter LoAdOrG is disabled ( diSAbLE ) and the
absolute mode is selected ( ABS ), the reference value is loaded by
pressing the
+
i
The reference value is loaded according to the selected
unit of measure.
14
Select digit
Select unit of measure
◀◀◀
) is selected, the incremental
key. The available options are
keys.
ELESA models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
Display:
battery change, unit of measure,
incremental mode, absolute mode,
processing, digits
On / Off
Set
function
5.5 Direct reset of incremental reference value
If parameter CLr_rEL is enabled ( EnAbLE ) and the
incremental mode is selected (
by pressing the
key.
If parameter CLr_rEL is disabled ( diSAbLE ), the display
can be set to zero only by switching from absolute mode ( ABS ) to
incremental mode (
◀◀◀
).
5.6 Access the absolute reference value setting
procedure
If parameter ProGOrG is enabled ( EnAbLE ) and the absolute
mode is selected ( ABS ), the absolute reference value setting
procedure is directly run by pressing
the
+
keys.
If parameter ProGOrG is disabled ( diSAbLE ), the absolute
reference value setting procedure can be run only accessing the
programming mode.
5.7 Access the offset value setting procedure
If parameter ProGOFS is enabled ( EnAbLE ) and the absolute
mode is selected ( ABS ), the offset value setting procedure is
directly run by pressing the
If parameter ProGOFS is disabled ( diSAbLE ), the
offset value setting procedure is directly run only accessing the
programming mode.
5.8 Switching the device ON and OFF
If parameter on-OFF is set to dirECt , the display is
immediately switch off by pressing the
If parameter on-OFF is set to dEL 'd , the display is switch off
by pressing the
key for 4 seconds.
), the display can be set to zero
◀◀◀
+
keys.
key.