Elesa MPI-R10 Operating Instructions Manual

Elesa MPI-R10 Operating Instructions Manual

Magnetic measuring system
Hide thumbs Also See for MPI-R10:

Advertisement

OPERATING INSTRUCTIONS
Magnetic measuring system
MPI-R10
MPI-R10-RF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPI-R10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elesa MPI-R10

  • Page 1 OPERATING INSTRUCTIONS Magnetic measuring system MPI-R10 MPI-R10-RF...
  • Page 2: Table Of Contents

    8. Programming mode 1. Safety Instructions 8.1 Programming of parameters with numeric values 2. Description 8.2 Device parameters (in alphabetical order) 2.1 Version - MPI-R10-RF 8.3 Main menu tree 3. Installation 8.4 Target menu tree 3.1 Display installation 8.5 Additional features 3.2 Sensor installation...
  • Page 3: Safety Instructions

    Connected to the dedicated sensor FC-MPI, and combined it is assembled and used properly, in the closest compliance with the magnetic band M-BAND-10, the MPI-R10 is a with this instructions manual and with the following specific complete system for the measurement of linear and angular safety precautions.
  • Page 4: Version - Mpi-R10-Rf

    1. Drill the panel according to the template dimensions reported. 2.1. Version – MPI-R10-RF 2. Remove all drilling burrs before fitting the MPI-R10. The MPI-R10-RF is compatible with Elesa wireless network 3. Fit the lower part of the case into the housing.
  • Page 5: Magnetic Band Installation

    Magnetic measuring system MPI-R10 MPI-R10-RF The maximum distance between the sensor and the magnetic Key Or Key Operating Mode Programming Mode band, to ensure a correct reading of the displacement, is 1mm. Combination Parameter Keep pressed for 3 sec to enter the selection/Confirm programming mode.
  • Page 6: System Switching On/Off

    Magnetic measuring system MPI-R10 MPI-R10-RF 7. Operating mode Key Or Key Operating Mode Programming Mode Combination 7.1. Absolute/incremental measuring mode selection Programmable with one of ABS-REL the following options (see the Press the key to select the absolute or incremental _ _ 0 _ _ _ 0 voice of the menu measuring mode.
  • Page 7: Direct Programming Of The Absolute

    M = T 7.6 Targets T < M < = T + Toll MPI-R10 allows to set up to 32 target positions to store M > T + Toll relevant machine configuration setting. To program the targets: - select tArGEtS in the main menu (see cap 8.3).
  • Page 8: Target Tolerance

    1.000000 0.00000 correction Using MPI-R10-RF , target positions can be sent from the PLC (the coefficient is automatically set to the indicators through the control unit. When a target is set, to 1.00000). the behaviour is the same as decribed in cap 7.6.
  • Page 9: Main Menu Tree

    Magnetic measuring system MPI-R10 MPI-R10-RF 8.3. Main menu tree Parameter Description Available options Default dir-- Programmable value --dir Res = 1:-999999 ÷ 999999 OriGin -999999 ÷ 999999 Res = 0.1:-99999.9 ÷ OFS 0 99999.9 OFFSET -999999 ÷ 999999 Res = 0.01:-9999.99 ÷...
  • Page 10: Additional Features

    These data can be scrolled pressing the key Please note these values and communicate them to Elesa in case of support needed. Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
  • Page 12 The Company Elesa S.p.A. can neither be held legally responsible nor liable for lacking or incorrect information and the ensuing consequences. The Company Elesa S.p.A. reserves the right to alter or improve the magnetic measuring system or parts of them without prior notice.