Electronic position indicators DD52R-E-RF Data transmission via radio frequency Contents 1. Safety Instructions 2. Assembly 3. Symbols on the display 4. Key function 5. Turning on the system Turning off the system 6. Operating mode System explanation Programming the network parameter (nEt id)
Tampering with this product may endanger the correctness and accuracy of its operation. In case of malfunction, do not attempt any repairs to the units and contact Elesa sales office. Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
Page 4
Electronic position indicators DD52R-E-RF Data transmission via radio frequency Mechanical and electrical characteristics Power supply Lithium battery CR2477 3.0 V Battery life 3 years 6-digit LCD of 12 mm height and special Display characters Reading scale -199999; 999999 Number of decimal digits...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 2. Assembly 1. Drill a Ø 6x10 mm hole in the body of the machine with a 30 mm centre distance from the shaft to fit the rear referring pin. 2. Fit the indicator onto the shaft and make sure that the referring pin fits into the hole.
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 4. Key function WARNINGS! The keys’ icons are conventionally shown with the display rotation set to 0° (default is 180°). FUNCTION Operating Programming mode mode Parameter selection / Access to the...
Data transmission via radio frequency 6. Operating mode 6.1 System description DD52R-E-RF, position indicators, with battery power supply, can be used on passing through shafts in any position to provide the reading of the absolute or incremental positioning of a machine component.
Electronic position indicators DD52R-E-RF Data transmission via radio frequency The menu function __0___ allows the customer to choose between the options d_tArG or d_to_GO (factory detail). Selecting d_tArG , when a new target position is set, the display will keep showing the present position.
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 6.5 Unit of measure selection Press the key to select the unit of measure needed. The options available are millimeters, inches and degrees. The measuring mode selected is shown on the display by the symbols:...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency The available options are: L_OrG : the reference value and the compensation value are set as shown above. Choose the desired offset among the 10 available values, then press the key to confirm;...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency The available options are: LOAd_t : choose available target positions, then press to confirm PrOG_t : choose to program one of the 32 available target positions, then press to start programming 6.9 Battery replacement...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 7. Programming mode Press the key for 3 seconds to enter the programming mode. Depending on the setting of PASS parameter (see table on page 16), the system may require you to enter a password.
Page 13
Electronic position indicators DD52R-E-RF Data transmission via radio frequency OriGin -99999 / 99999 OFS 0 OFFSET -99999 / 99999 OFS 9 StEP 000.01 / 100.00 Inch 0.01 0.01 0.01 0.001 0° diSPL 180° SPEEd 1000 nEt id rAdio ch 01...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 7.3 Parameters The available parameters and their descriptions are listed in the following table. Standard Parameter Description Available options value Rotation --o clockwise direction o-- counterclockwise Absolute -99999 ; 99999 OriGin 0000.0...
Page 15
Electronic position indicators DD52R-E-RF Data transmission via radio frequency Standard Parameter Description Available options value Key function ALL : selectable units of _ _ _ _ _ 0 measure: mm, inch, D nodEG : selectable units of measure: mm, inch...
Page 16
Electronic position indicators DD52R-E-RF Data transmission via radio frequency Standard Parameter Description Available options value The key combination activates 0 _ _ _ _ 0 P_OrG combination the direct programming of the function following parameters: P_OrG : parameter OrG P_StP : parameter StEP...
Electronic position indicators DD52R-E-RF Data transmission via radio frequency 8. Problem solving Message on the Description Action display The system continues Exceeding the to measure reading scale displacements; (-199999; 999999). the value will be _ _ _ _ _ _...
Need help?
Do you have a question about the DD52R-E-RF and is the answer not in the manual?
Questions and answers