Technical data and dimension sheets
11

General information

11.2
General information
11.2.1
Air admission and accessibility
11.3

Technical data

11.3.1
General technical data
Input
®
MOVIMOT
flexible
flange size electronics cover
Sizes of the electronics cover
Type of electronics cover
Nominal output current
Nominal supply voltage AC
(to EN 50160)
Nominal line current
Line frequency
368
Operating Instructions – MOVIMOT
When installing the driven machine, make sure there is enough space in axial and ra-
dial direction for a sufficient supply of cooling air and unobstructed heat dissipation.
DFC...-
0020...
2.0 A
U
line
I
1.8 A
line
I
5.4 A
max
f
line
®
flexible
MMF.1..
Size 1
without cooling fins
DFC...-
DFC...-
0025...
0032...
2.5 A
3.2 A
3 × AC 380 V – 500 V
2.25 A
2.88 A
6.75 A
8.64 A
50 – 60 Hz ± 10%
Size 1
with cooling fins
DFC...-
DFC...-
0040...
0055...
4.0 A
5.5 A
3.6 A
4.95 A
10.8 A
14.85 A