Table of contents Table of contents General information........................ 4 About this documentation .................... 4 Rights to claim under limited warranty ................ 4 Other applicable documentation .................. 4 Copyright notice ...................... 4 System overview ........................ 5 ® System overview of MOVITRAC LTE-B+ .............. 5 ® System overview of MOVITRAC LTP-B ...
General information About this documentation General information About this documentation This documentation is an integral part of the product. The documentation is intended for all employees who perform assembly, installation, startup, and service work on the product. Make sure this documentation is accessible and legible. Ensure that persons respons- ible for the machinery and its operation as well as persons who work on the device in- dependently have read through the documentation carefully and understood it.
System overview System overview of MOVITRAC® LTE-B+ System overview System overview of MOVITRAC ® LTE-B+ ® System overview of MOVITRAC LTE-B+ Frequency inverter • Performance classes: 0.37 – 37 kW LTE-B+ • Voltage range: 1 × 115 V, 1 × 230 V, 3 × 230 V, 3 × 400 V, • Overload capacity: 150% for 60 s, 175% for 2 s For further information on this device, refer to the fol- lowing documents: •...
Page 6
System overview System overview of MOVITRAC® LTE-B+ Software ® MOVITOOLS MotionStudio Software for parameterization and data backup Software for parameterization, data backup, firmware LT Shell updates, and scope Manual – Accessories...
System overview System overview of MOVITRAC® LTP-B System overview of MOVITRAC ® LTP-B ® System overview of MOVITRAC LTP-B Frequency inverters LTP-B • Performance classes: 0.75 – 160 kW • Voltage range: 1 × 230 V, 3 × 230 V, 3 × 400 V, 3 × 575 V L1/L L2/N L3 • Overload capacity: 150% for 60 s, 175% for 2 s For further information on this device, refer to the fol- lowing documents: •...
Page 8
System overview System overview of MOVITRAC® LTP-B Remote keypads LT BG OLED A Full-text OLED keypad Accessories Cable set A Basic package Cable set B Expansion package Cable set C PC engineering package ® LTBP-C Bluetooth parameter module Software ® MOVITOOLS MotionStudio Software for parameterization and data backup...
Flatpack resistors Technical data Flatpack resistors ® A special resistor in flat design is available for MOVITRAC Braking resistor type Part number LTE-B+ LTP-B BW LT 100 002 18208770 BW LT 050 002 55 18218342 − 2)3) BW LT 033 005 18201938 − 1) For sizes 2 and 3. 2) No UL approval.
Flatpack resistors Installation IP20 Installation IP20 Read the relevant operating instructions before starting work. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the device and at the terminals up to 10 minutes after disconnection from the power supply.
Page 11
Flatpack resistors Installation IP20 2. Attach the resistor by screwing the 2 supplied screws into the tapped holes [A] on the rear of the unit. 9007212651028747 3. Make sure that the retaining screws and the spring washers are fastened securely before starting operation.
Flatpack resistors Installation IP55 Installation IP55 Read the corresponding operating instructions before you start working. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the unit and at the terminals up to 10 minutes after disconnection from the power supply. Severe or fatal injuries.
Page 13
Flatpack resistors Installation IP55 3. Push the braking resistor into the slot [B] on the heat sink. The serrated side of the braking resistor must point outward. 13943460363 4. Attach the braking resistor by screwing the supplied screws through the holes [C] into the tapped holes.
Page 14
Flatpack resistors Installation IP55 3.3.2 Installation size 5: 1. Remove the fan insert by pressing in the tabs [A]. There are 2 on each side of the housing. 13943467659 2. Push the braking resistor into one of the slots [B] on the heat sink. In the frequency inverter 2 braking resistors can be connected in parallel.
Flatpack resistors Startup and operation 4. Attach the braking resistor by inserting the supplied screws through the holes [C] into the tapped holes on the side of the frequency inverter. 5. Position the fan insert back on the housing. 6. Connect the braking resistor to the terminals "+" or "DC+" and "BR" of the fre- quency inverter.
EMC components EMC components You can install EMC components to improve interference immunity. EMC components, such as line filters and output filters, require a large-area, metallic contact with the frequency inverter via a shared mounting plate. They must be placed as close to the corresponding unit as possible in order to keep the lines short between the EMC component and the unit (max.
NF line filter Electromagnetic compatibility NF line filter Type LTE-B+ LTP-B NF LT xxx xxx xx X = available − = not available A line filter reduces interference emission via the line cable, which is generated by the frequency inverter due to its operating principle. It mainly serves to meet interference voltage limit requirements in the frequency range from 150 ...
Page 18
NF line filter Electromagnetic compatibility Device type with filter Cat. C1 (class B) Cat. C2 (class A) Cat. C3 In accordance with EN 61800-3 230 V, 3-phase Use an external filter No additional filtering required. of the type LTE-B xxxx 2A3-x-xx Use a shielded motor cable. NF LT xxx xxx.
NF line filter Technical data Technical data 5.2.1 IP20/IP66, 1 x 200 – 250 V, 10 – 25 A Type Unit NF LT 010 201-20 NF LT 025 201-20 NF LT 010 201-66 NF LT 025 201-66 Part number 18411029 18411037 18411134 18411142 Nominal voltage U (in accord-...
Page 20
NF line filter Technical data 5.2.2 IP20/IP66, 3 x 220 – 500 V, 6 – 300 A Type Unit NF LT 006 503-20 NF LT 016 503-20 NF LT 025 503-20 Part number 18411045 18411053 18411061 Nominal voltage U (in accord- 3 x AC 220 – 480, 48 – 62 Hz ance with EN 50160) Rated current I Leakage current I...
Page 21
NF line filter Technical data 5.2.3 IP20, 3 × 600 V, 6 – 25 A Type Unit NF LT 006 603-20 NF LT 016 603-20 NF LT 025 603-20 Part number 18411223 18411231 18411258 Nominal voltage U (in accord- 3 x AC 600, 48 – 62 Hz ance with EN 50160) Rated current I Leakage current I...
NF line filter Dimensions Dimensions 5.3.1 IP20, 1 x AC 200 – 250 V, 10 – 25 A 12694590091 Part number PE connec- tion NF LT 010 201-20 2 x M6 12.5 NF LT 025 201-20 2 x M6 12.5 Manual – Accessories...
Page 23
NF line filter Dimensions 5.3.2 IP66, 1 x AC 200 – 250 V, 10 – 25 A 12263312139 Part number PE con- nection NF LT 010 201-66 3G2.5 12.5 12.5 NF LT 025 201-66 3G4.0 12.5 12.5 Manual – Accessories...
Page 24
NF line filter Dimensions 5.3.3 IP20, 3 x AC 220 – 480 V, 6 – 50 A 12263306379 Part number PE connec- tion NF LT 006 503-20 2 x M6 NF LT 016 503-20 2 x M6 NF LT 025 503-20 2 x M6 NF LT 050 503-20 2 x M6 Manual –...
Page 25
NF line filter Dimensions 5.3.4 IP66, 3 x AC 220 – 480 V, 6 – 25 A NF LT 006 503-66, NF LT 016 503-66 12263312139 NF LT 025 503-66 12686783883 Manual – Accessories...
Page 26
NF line filter Dimensions Part number PE con- nection NF LT 006 503-66 4G1.5 NF LT 016 503-66 4G2.5 12.5 NF LT 025 503-66 4G4.0 – – – 5.3.5 IP00/IP20, 3 x AC 220 – 400 V, 80 – 300 A NF LT 080 503-20, NF LT 180 503-20 NF LT 300 503-00 12694584203 12694587147...
Page 27
NF line filter Dimensions 5.3.6 IP20, 3 x AC 600 V/690 V, 6 – 25 A NF LT 006 603-20, NF LT 016 603-20, NF LT 025 603-20 12263310219 Part number PE connection NF LT 006 603-20 2 x M6 NF LT 016 603-20 2 x M6 12.5 NF LT 025 603-20 2 x M6...
Page 28
NF line filter Dimensions 5.3.7 IP20, 3 x AC 600 V/690 V, 50 A NF LT 050 603-20 12263306379 Part number PE connection NF LT 050 603-20 2 x M6 – – Manual – Accessories...
Page 29
NF line filter Dimensions 5.3.8 IP20, 3 x AC 600 V/690 V, 80 – 180 A NF LT 080 603-20, NF LT 180 603-20 12694584203 Part number PE connection NF LT 080 603-20 2 x M10 – – – NF LT 180 603-20 2 x M10 – –...
NF line filter Installation Installation ® Disconnect the MOVITRAC LT from the supply system before starting to work. Ob- serve the corresponding operating instructions. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the device and at the terminals up to 10 minutes after disconnection from the power supply.
Line chokes General Line chokes The following characteristics are based on the use of line chokes for the overall sys- tem: • Reduction of harmonic distortions in the power supply • To support overvoltage protection • To smoothen the line current, to reduce harmonics •...
Line chokes Installation Installation ® Disconnect the MOVITRAC LT from the supply system before starting to work. Ob- serve the corresponding operating instructions. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the device and at the terminals up to 10 minutes after disconnection from the power supply.
Output chokes Output chokes Type LTE-B+ LTP-B HD LT xxx xxx xx X = available − = not available 3186116363 Output chokes improve the quality of the output wave shape. When an output choke is used, the maximum cable length can be doubled. For information on cable length, refer to the technical data in the operating instructions or in the catalog of the fre- ®...
Output chokes Technical data Technical data 7.1.1 IP20, 3 × 200 – 500 V, 8 – 75 A Type Unit HD LT 008 200 53-20 HD LT 012 130 53-20 HD LT 030 050 53-20 HD LT 075 022 53-20 Part number 18201695 18201709 18201717...
Output chokes Installation Installation ® Disconnect the MOVITRAC LT from the supply system before installation. Observe the corresponding operating instructions. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the unit and at the terminals up to 10 minutes after disconnection from the power supply. Severe or fatal injuries.
Shield plate IP20 Shield plate IP20 Type Part number LTE-B+ LTP-B LT SB 23 A 28214994 1) Only for sizes 2 and 3. X = available − = not available 13406635275 [1] Earth connection [2] Terminal for motor cable [3] Adjustment screw for BG 2 and 3 [4] Connection for back panel installation Manual –...
Shield plate IP20 Installation Installation ® Disconnect the MOVITRAC LT from the supply system before starting to work. Ob- serve the corresponding operating instructions. WARNING Danger of electric shock. Dangerous voltage levels may still be present inside the device and at the terminals up to 10 minutes after disconnection from the power supply.
Need help?
Do you have a question about the MOVITRAC LTE-B+ and is the answer not in the manual?
Questions and answers