5.2 Performance curve

[ m ]
9
8
7
6
5
4
3
2
1
2
Values shown are for the KTP 1000 pump with cutting / macerating assembly for the Aqualift F,
Aqualift F Compact and the Ecolift)
Max. pumping volume Q (m
Max. pumping volume Q (liter/sec.)
Pumping height
H (mWS)
5.3 Electrical paramaters
Power type
Voltage
class
AC
230V
Allowable operating temperature (surroundings) 0 ....50 deg C
Maximum allowable wastewater temperature (short term) - up to 40 deg C
Operating noise: < 70 db
5. Technical Data
4
6
/hour)
1,0
2,0
3
0,3
0,6
9,5
8,9
Current
Motor Power P1/P2
4,9 Amp
1000 W / 620 W
[ Qm
8
10
3
3,0
4,0
5,0
6,0
0,8
1,1
1,4
1,7
8,3
7,6
6,9
6,1
rpm
2800 rpm
29
/h ]
7,0
8,0
9,0
1,9
2,2
2,5
5,2
4,2
3,2
Motor Protect.
integrated
thermal
10,0
10,9
2,8
3,0
2,1
1,0
Operating
class
S3-30%