1. Turn off the heater (14) and allow material to circulate for 15 minutes.
2. Reduce the pump pressure to 0 bar (0 psi).
3. Open the drain valve (11). Following the material manufacturer's
recommended handling and disposal procedures, drain material from
the system.
4. Close the circulation valve (10).
5. Adjust the air pressure to the pump until it is stroking 8–10 strokes per
minute.
6. Remove the siphon hose (13) from the coating material container (12)
and place into the solvent bucket.
7. Flush the system with solvent for approximately 15 minutes.
8. Trigger the gun several times to clean it.
9. Close the drain valve (11).
10. Circulate solvent through the system for approximately 15 minutes.
11. Open the drain valve.
12. Remove pressure from the pump.
NOTE: Leave solvent in the system when not in use.