Daily Maintenance - Nordson A16A Customer Product Manual

Inside stripe gun
Table of Contents

Advertisement

Daily Maintenance

Component
A16A Gun
Fluid Filter
Air Filter
E 2020 Nordson Corporation
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
The following paragraphs provide daily preventive maintenance procedures
for the A16A inside stripe gun. Experience in gun operation will indicate if
less frequent cleaning is required.
WARNING: Make sure all power, air pressure, and fluid pressure is
removed from the gun before performing preventive maintenance
procedures.
WARNING: Use appropriate respiratory and skin protection when using
coating materials and solvents. Obtain and read the Material Safety Data
Sheets from the manufacturer before use, and follow the manufacturer's
recommended handling and disposal procedures.
Remove dirt and dried coating material from the gun exterior with a
solvent-soaked cloth. Do not soak any components in solvent. Some solvents
may affect O-rings and seals.
1. Remove the filter screen from the high-pressure fluid filter.
2. Inspect the filter screen and discard if ruptured or distorted.
3. If the filter screen is not defective, soak it in a compatible solvent.
4. Place a clean filter screen in the high-pressure fluid filter.
1. Drain the air filter.
2. Remove the air filter bowl and dump out any remaining water and dirt.
3. Remove the filter element, wash in soapy water, rinse, dry and reuse.
Maintenance Procedure
A16A Inside Stripe Gun
Part 107907-06
11