Common Service Tool (Cst); Connecting Cst - Husqvarna 967187001 Workshop Manual

Rider battery
Table of Contents

Advertisement

Troubleshooting with Common Service Tool

9.1 Common Service Tool (CST)

The Common Service Tool is for the Husqvarna
Rider Battery.
It is intended for use with a laptop computer
(PC not included). The software is available for
download from the Husqvarna website and is
compatible with Windows XP and later.
The Service Tool communicates with the machine.
It is also possible to enter service notes linked to
the product ID. These records can then be read,
for example at the next service.
Common Service Tool offers three different
methods of troubleshooting the machine.
• Auto test
• Manual test
• Manual drive with logging

9.2 Connecting CST

A USB cable of "type A" to "type B" is coupled to
the control unit (CCU) for connecting between the
machine and a computer.
WARNING!
The electronics may be damaged if the
USB cable is connected incorrectly
during trouble shooting with CST.
WARNING!
The normal safety functions may
be deactivated when connected the
machine to CST via a USB cable.
1
Loosen the top cover on the rear to access the
control unit.
2
Loosen the rubber plug on top of the control unit to
access the USB port.
3
Connect the USB cable to the control unit and a
computer with the Common Service Tool (CST)
installed, and run the program.
(The machine must be powered when trouble
shooting.)
78
English –
A
B
USB cable, ''type A'' to ''type B''

Advertisement