In order to test for faults on +5 V in Cable 2, recon-
nect the flat pin and receptacle so that Cable 2
shall have +5 V.
Start by checking that +5 V is not short circuited in
the battery charger connector. The orange lead in
this connector must not make contact with the blue
lead (GND) in this connector. Check the connector,
and if this one looks good, go to item 7.
7
The next test is to disconnect the control panel by
unplugging the connector that is directly under the
control panel. If +5 V returns after unplugging the
connector, the fault will be inside the control panel.
The control panel must then be changed. If the
fault persists go to item 8.
8
Check the microswitch at the cutting deck acti-
vation lever. +5 V comes in the orange lead to
this microswitch. See if there is a coupling to the
chassis if the machine has cutting motor controls
version 2.
Unplug the flat pin receptacle with the orange
cable from the microswitch to see if +5 V returns. If
the fault persists, change microswitch.
+5V
Charging connector mounted in the machine
Cuttingdeck on switch 1
Cuttingdeck on switch 2
CST Autotest