1.5 Servicing tools The manual gives information about necessary servicing tools. Always use original tools from Husqvarna. 1856 - 001 - 14.04.2022 Introduction - 3...
Note: Save all warnings and instructions. • Use the BLi100, BLi200, BLi200X, BLi300 batteries as a power supply for the related Husqvarna products only. To prevent injury, do not use the battery as a power supply for other devices.
3 Symbols on the product Be careful and use the product correctly. This product can cause serious injury or death to the operator or others. Read the operator's manual carefully and make sure that you understand the instructions before use. Do not use the product in rain.
4 To charge the battery Charge the battery before the first time of operation. A new battery is charged 30%. Push the battery indicator button to get information of the state of charge of the battery. CAUTION: Only charge the battery when the ambient temperature is between 5°C (41°F) and 40°C (114°F).
6.2.2 To connect the common service tool (CST) CAUTION: If you install firmware to a new spare WARNING: Do not push the power trigger. part, make sure that you know the Husqvarna The motor can operate when the product is identification number (HID). The identification in servicing mode.
7 Product overview 1. Battery 2. Type plate 3. Battery indicator button 4. LED indicator for errors 5. LED indicator for the state of charge (SoC) 10 - Product overview 1856 - 001 - 14.04.2022...
7. Push out the battery connector from the slot. Note: Push the top cover in the direction of the casing when you install the screws. 8.3 To replace the casing BLi100, BLi200, BLi200X WARNING: Risk of electric shock. Use tools with electric insulation.
Page 13
3. Remove the 4 screws. 7. Remove the battery pack. Hold the battery pack at the ends of the circuit board to prevent short circuit. 4. Put the screws at a safe distance from the battery. 5. Push and hold the clips and remove the top cover and the clips.
9 Troubleshooting 9.1 Troubleshooting Symptoms Cause Solution LED indicator for Temporary error. The BMS have detected a temperature, voltage or cur- errors flashes. rent outside of the optimal limits. The error LED flashes until the conditions return to normal. Charge the battery. LED indicator for Permanent error.