Siemens SINUMERIK ONE PPU 1740 Series Equipment Manual page 70

Table of Contents

Advertisement

Interface description
7.3 Ethernet
Table 7-5
B = Bidirectional
Note
The PROFINET interface has what is known as autocrossing functionality, i.e. when required,
transmit and receive lines are switched over. Thus, no crossover cables are necessary.
Cable specification
For PROFINET, you always require a data transmission rate of 100 Mbit/s (Fast Ethernet) in full
duplex mode. For data transfer purposes, you can use twisted-pair copper cables (4-wire,
100Base-T).
Table 7-6
Characteristic
Connector type
Cable type
Max. cable length
70
Assignment of PROFINET interface X160 in the 10/100 MBit/s mode
Connector
Pin
1
2
3
4
5
6
7
8
Shield
-
-
Cable specification for X150 ports 1, 2
Name
Type
DA+
B
DA-
DB+
DC+
DC-
DB-
DD+
DD-
-
-
LED green
-
(Link)
LED orange
-
(Activity)
Version
RJ45 socket
Industrial Ethernet cable (as of CAT5)
100 m
Equipment Manual, 01/2019, A5E47615272B AA
Remark
Bidirectional pair A+
Bidirectional pair A-
Bidirectional pair B+
Bidirectional pair C+
Bidirectional pair C-
Bidirectional pair B-
Bidirectional pair D+
Bidirectional pair D-
On connector housing
Lights up orange: 1000 Mbit/s
Off: No or faulty connection
Flashes: Data exchange
Off: No data exchange
PPU 1740