7-Segment Display - Siemens SINUMERIK ONE PPU 1740 Series Equipment Manual

Table of Contents

Advertisement

3.2.3

7-segment display

Figure 3-7
Displaying messages
● It serves to output status information during commissioning, ramp-up and cyclical operation.
The 7-segment display is visible on the rear side of the PPU.
● During normal operation, "6" appears here and the dot flashes.
Load BIOS
7-segment display
Booting the basic system
7-segment display
1 (begin)
2 (prepfs)
3 (hostname, loopback) The name is set and the loopback interface configured.
4 (syslog)
5 (network)
6 (PPU:rtai, TCU:tcu‐
config))
7 (lsh)
8 (PPU:ftpd,
TCU:mtouch)
9 (PPU:tcuservices,
TCU:usbexport)
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA
7-segment display
Meaning
00
Before loading the Master Boot Record (MBR) from the SD card
01
Before starting the Master Boot Record (MBR) codes
02
Master Boot Record (MBR) code has started
03
Second stage of the boot loader has started, before reading the configuration
file
04
Before loading the kernel
05
Before starting the kernel
Meaning
Basis initializations
Cleaning up and preparing the file system
Starting the system logging
Starting the CFS class 1, provide the network interfaces.
Initializing the network interfaces and the firewall
Starting the time server (ntpd)
Starting the SSH server (generate a host key if one is still not available).
Starting the FTP server
Starting the TCU services (TFTP, VNC)
System characteristics
3.2 Operator controls and display elements
31