Siemens SINUMERIK ONE PPU 1740 Series Equipment Manual page 73

Table of Contents

Advertisement

Pin
12
13
14
X252 pin assignment
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
NOTICE
Shielded signal cables for analog signals
To ensure safe, fault-free operation of the system, shielded cables with shield connection
should be used for the wiring of the analog outputs.
Use
The following assignment applies to the terminals:
● Ten signals can each be assigned to X122 and X132:
– Six digital inputs
– Four bidirectional digital inputs/outputs
PPU 1740
Equipment Manual, 01/2019, A5E47615272B AA
Signal name
O3
DOUT3
O4
DOUT4
M3
MEXT3
Signal name
AO
AOUT
AM
AGND
IN9
DIN9
IN10
DIN10
IN11
DIN11
IN12
DIN12
M4
MEXT4
P3
P24EXT3
O9
DOUT9
O10
DOUT10
M3
MEXT3
O11
DOUT11
O12
DOUT12
M3
MEXT3
NC variable
$A_OUT[3]
$A_OUT[4]
NC variable
Meaning
Analog output (voltage for analog axis/spindle)
Analog ground
$A_IN[9]
Digital NC input 9
$A_IN[10]
Digital NC input 10
$A_IN[11]
Digital NC input 11
$A_IN[12]
Digital NC input 12
Ground for pins 3...6
+24 V power supply
$A_OUT[9]
Digital NC output 9
$A_OUT[10]
Digital NC output 10
Ground for pins 9, 10, 12, 13
--
● Without analog axis/spindle:
Digital NC output 11
● With analog axis/spindle:
Controller enable in accordance with
MD30134 $MA_IS_UNIPOLAR_OUTPUT
--
● Without analog axis/spindle:
Digital NC output 12
● With analog axis/spindle:
Traversing direction in accordance with
MD30134 $MA_IS_UNIPOLAR_OUTPUT
Ground for pins 9, 10, 12, 13
Interface description
7.4 Digital inputs/outputs
Meaning
Digital NC output 3
Digital NC output 4
Ground for pins 9, 10, 12, 13
73