BAYKON BX11 Series User Manual page 41

Smart process indicator
Hide thumbs Also See for BX11 Series:
Table of Contents

Advertisement

Communication
Voltage output
Current output
D/A Converter
Max. cable length
Max. load resistance
(current output )
Min. load resistance
(Voltage output )
Communication
RS-485
Response speed
Max Stations
Communication
Data rate
GSD file
Installations
Max. Stations
Isolation
Response speed
Communication
Data rate
GSDML file
TCP/IP settings
Topology
Installation
Web client
Isolation
Response speed
Communication
Transmission rate
TCP/IP settings
Installation
Web client
Response speed
BX11 Smart Process Indicator, User Manual, Rev. 1.8, May 2017
BX11 AN Analogue
0-5 VDC, 0-10 VDC
4-20mA, 0-20mA
16 bit
300 meter
500
10 k
BX11 MB Modbus-RTU
1200 to 115200 baudrate, 8N1 / 7O1 / 7E1 / 8O1 / 8E1
Up to 4 ms. response delay after read/write commands
Up to 31 stations per segment
BX11 PB Profibus DPV1
Up to 12000 kbit/s with automatic baud rate detection
Generic GSD-file provided
Shielded twisted pair cable
Line length depending on physical media and transmission speed
Up to 32 stations per segment, up to 126 stations per network
Galvanically isolated bus electronics
Up to 4 ms. response delay after read/write commands
BX11 PN Profinet
100 Mbit/s, full duplex
Generic GSDML-file provided
DHCP or manual IP assign over EtherX PC Software.
Device identity customization
Line, Bus, Star or Tree topology depending on physical media
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Available
Galvanically isolated bus electronics
Up to 4 ms. response delay after read/write commands.
BX11 EN Ethernet
10 Mbit/s, half duplex
Manual IP assign over EtherX PC Software or by keys in programming mode.
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Available
Up to 4 ms. response delay after read/write commands