BAYKON BX11 Series User Manual page 32

Smart process indicator
Hide thumbs Also See for BX11 Series:
Table of Contents

Advertisement

0 : No.
1 : (Output1 = Sp1), (Output2 = Sp2), (Output3 = Sp3), (Output4 = Sp4), (Output5 = Sp5 )
2 : (Output1 = Sp1), (Output2 = Sp2), (Output3 = Sp3), (Output4 = Sp4), (Output5 = Stable )
3 : (Output1 = Sp1), (Output2 = Sp2), (Output3 = Sp3), (Output4 = Sp4), (Output5 = Error )
4 : (Output1 = Sp1), (Output2 = Sp2), (Output3 = Sp3), (Output4 = Sp4), (Output5 = Centre of zero)
5 : Functional outputs ( Refer to [ 7-- ] parameter group )
6 : Setpoint of real indicated weight
7 : Setpoint of gross weight
8 : Control mode-1
9 : Control mode-2
[131 0] Input 1
0 : Not used
6 : Hold during active
[132 0] Input 2
0 : Not used
6 : Hold during active
[133 0] Input 3
0 : Not used
6 : Hold during active
[134 0] Input 4
0 : Not used
6 : Hold during active
[70-] Digital Output Functions
Warning
The parameter [130] shall be program to '5' to use these functions.
:
In this block, the digital outputs are programmed for the functions indicated in the table below.
Threshold Output :
2 set point values are entered. SP1 is
the point that the output goes active
when the weight increased from
SP1_H. SP1_L is the point that the
output drops to passive state when
the weight decreased to SP1_L.
Inverse function is available.
BX11 Smart Process Indicator, User Manual, Rev. 1.8, May 2017
1 : Zero
2 : Tare
7 : Peak during active
1 : Zero
2 : Tare
7 : Peak during active
1 : Zero
2 : Tare
7 : Peak during active
1 : Zero
2 : Tare
7 : Peak during active
3 : Clear
4 : Print
8 : Field bus input
3 : Clear
4 : Print
8 : Field bus input
3 : Clear
4 : Print
8 : Field bus input
3 : Clear
4 : Print
8 : Field bus input
5 : Key lock
5 : Key lock
5 : Key lock
5 : Key lock
Page 30 of 48