Control Mode-1:
Setpoints are entered as
SP1<SP2<SP3<SP4<SP5
and outputs are activated as indicated in
the drawing as seen on the right. This
mode can be used for checkweighing,
sorting, filling, multicomponent batching
etc.
Refer to parameter [ 130 ] on Page 29.
Control Mode-2:
Setpoints are entered as
SP1<SP2<SP3<SP4<SP5
and outputs are activated as indicated in
the drawing as seen on the right. This
mode can be used for checkweighing,
sorting, filling, multicomponent batching
etc.
Refer to parameter [ 130 ] on Page 29.
Threshold Output:
2 set point values are entered. SP1 is the
point that the output goes active when the
weight increased from SP1_H. SP1_L is
the point that the output drops to passive
state when the weight decreased to
SP1_L.
Inverse function is available.
Refer to parameter [ 7-- ] on Page 30.