Fast Continuous Data Output; Print Mode - BAYKON BX11 Series User Manual

Smart process indicator
Hide thumbs Also See for BX11 Series:
Table of Contents

Advertisement

CHK (Checksum) = 0 – ( STX + STATUS A + ..... + LF )
Error Messages: UNDER, OVER, A.OUT, L-VOLT, H-VOLT, are represented in Indicated data fields.
Note
The weight data is represented with right aligned, error messages are represented with left
:
aligned.
Important
The CR and LF shall be enabled for Baykon remote display interfacing.
:

7.2 Fast Continuous Data Output

Fast continuous "indicated weight" data output can be used only for the instruments which can
communicate fast. The output rate is related with the baud rate. Use higher baud rate for faster data
rate. Received ASCII codes of P(print), Z(zero), T(tare) or C(clear) letters, the indicator will act like the
related keys are pressed. CR and LF can be enabled in the related parameter.
The data format of the fast continuous data output is;
[STX][STATUS][SIGN][WEIGHT VALUE][CR][LF]
Examples
:

7.3 Print Mode

The format of the data output in Print mode can be selected in 3 different type forms in the
parameter group [ 04- ] . Only continuous format is available more than one interface.
Single Line
You can send the data in single line like below by pressing <
CN:
21
BX11 Smart Process Indicator, User Manual, Rev. 1.8, May 2017
S+000123.4
(weight is stable and 123.4)
D+000123.4
(weight is dynamic and 123.4)
+
(Over load)
-
(Under load)
O
(ADC out error)
G:
3.000kg
> key as;
Enter
T:
1.000kg
N:
2.000kg
Page 36 of 48