BAYKON BX11 Series User Manual page 19

Smart process indicator
Hide thumbs Also See for BX11 Series:
Table of Contents

Advertisement

Setpoint of absolute indicated weight
The absolute indicated weight value is
compared with the setpoint entry and the
output state is activated if the absolute
weight is higher than setpoint. As an
example, setpoint 1 is 100 kg in the
drawing on the right.
Refer to parameter [ 130 ]=1,2,3,4 on
Page 29.
Setpoint of gross weight
The output state is activated during the
heavier gross loadings at gross or net
weight indications. This feature can be
used to produce alarm signal at empty or
over weighted scales, tanks etc. As an
example, setpoint 1 is 100 kg in the
drawing on the right.
Refer to parameter [ 130 ] on Page 29.
Setpoint of real indicated weight
The + or - sign of the setpoint can be
entered. The output signal is produced if ;
Positive setpoint : The output is activated if
the weight is heavier than the loading.
Refer to setpoint 1 in the drawing.
Negative setpoint : The output is activated
if the negative net weight is lighter than
the setpoint. Refer to setpoint 2 in the
drawing.
As an example, setpoint 1 is 100 kg and
setpoint 2 is -200 kg in the drawing on the
right.
To enter the negative or positive value,
long press < Tare > key while the set
point value is seen on the display.
Refer to parameter [ 130 ] on Page 29.
BX11 Smart Process Indicator, User Manual, Rev. 1.8, May 2017