9.4
Setting the Panel when Mains Fails
Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to
Set and Unset the control panel during a mains fail if allowed in System Option 2 and no further action is required.
Full functionality of the control panel is available during mains fail.
9.5
Programming Set Modes.
Any zone may be programmed to be any one of the following:
E
Entry / Exit =
Access =
H
F
24 Hour =
Fire =
The attribute for each zone is selected by pressing
When the required symbol appears pressing the
and the next zone will automatically be selected.
NOTE: On pressing
automatically.
To programme SET A enter
To programme SET B enter
To programme SET C enter
To programme SET D enter
Should you wish to view any zone status within a Set mode use the same procedure,
but do not scroll the
8, the progamme for the required SET will be stored automatically and the program will be exited.
9.6
Setting the Alarm Bell Time
To adjust the alarm bell cut off time.
followed by the required time in minutes (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The alarm bell cut off time for the Sterling 10 is factory set to 20 minutes.
9.7
Setting Entry Time
To set the required Entry time.
followed by the time required in seconds (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Entry time is factory set to 30 seconds.
9.8
Setting Exit Time
To set the required Exit time
followed by the time required in seconds (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Exit time is factory set to 30 seconds.
9.9
Setting Bell Delay
To set the required Bell Delay.
followed by the time required in minutes(
Incorrect entry gives an audible error tone and correct entry gives three bleeps. Bell Delay is factory set to
zero minutes.
9.10
Setting Communication Delay
To set the required Communication Delay
followed by the time required in seconds (
Rins136 Issue 9
A
T
Tamper =
Momentary Keyswitch =
after selecting the attribute for zone 8, the programme for the required SET will be stored
Then select attribute for each zone.
Then select attribute for each zone.
Then select attribute for each zone.
Then select attribute for each zone.
keys. Enter
to select the attribute for the zone. After selecting the attribute for zone
Enter
to
Enter
to
Enter
to
Enter
to
to
I
Immediate =
Y
Latch Keyswitch =
or
until the required symbol appears in the display.
key will select the attribute, a two tone acceptance will be heard
minutes) followed by
seconds) followed by
seconds) followed by
minutes) followed by
Enter
seconds) followed by
O
Omitted =
.
.
.
.
.
Page 23