11.5

Setting the Panel when Mains Fails

Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to
Set and Unset the control panel during a mains fail and no further action is required.
Full functionality of the control panel is available during mains fail.
11.6

Programming Set Modes.

Any zone may be programmed to be any one of the following:
Entry / Exit
Immediate
Fire
Momentary Keyswitch
The attribute for each zone is selected by pressing or until the required symbol appears in the display.
The following example shows the key press sequence required to program SET A from the factory settings shown on
page 17 with the following new attributes:
Zone 1 = Entry / Exit
Zone 5 = Immediate
Enter
followed by
(select SET A )
then
NOTE: On pressing
To programme SET B
and to programme SET D
Should you wish to view any zone status within a Set mode use the same procedure,
but do not scroll the
11.7

Setting the Alarm Bell Time

To adjust the alarm bell cut off time.
followed by the required time in minutes (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The alarm bell cut off time for the Atlas 8 is factory set to 20 minutes.
11.8

Setting Entry Time

To set the required Entry time.
followed by the time required in seconds (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Entry time is factory set to 30 seconds.
11.9

Setting Exit Time

To set the required Exit time
followed by the time required in seconds (
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Exit time is factory set to 30 seconds.
Page 20
= E
Access
= I
Omitted
= F
Personal Attack = P
= y
Latch Keyswitch = d
Zone 2 = Access
Zone 6 = Tamper
then
then
e
a
then
P
after selecting the attribute for zone 8, the programme for SET A will be stored automatically.
enter
to programme SET C
enter
keys.
Enter to exit.
Enter
to
Enter
to
Enter
to
= A
Tamper
= O
24 Hour
Zone 3 = Immediate
Zone 7 = Personal Attack Zone 8 = Fire
then
then
then
I
I
I
minutes) followed by
seconds) followed by
) followed by
= t
= H
Zone 4 = Immediate
t
F
enter
.
.
.