CEL electrode setup (Cel-elec.-Setup)

CEL setup

Cel setup param-
Starting duration
eters
Duration of the starting current for a hot start
Unit
Setting range
Factory setting
To obtain optimum welding results, it will sometimes be necessary to adjust the Hot start
function.
Advantages
-
-
-
Voltage cut-off
Welding voltage limitation
Unit
Setting range
Factory setting
The arc length essentially depends on the welding voltage. To end the welding operation,
it is usually necessary to make a pronounced lifting motion of the rod electrode away from
the workpiece. With the 'Voltage cut-off' parameter, the welding voltage can be limited to
a value that makes it possible to end the welding operation simply by lifting the rod elec-
trode slightly.
NOTE! If, during welding, you often find that the welding operation is ended unintention-
ally, set the 'Voltage cut-off' parameter to a higher value.
Dynamic rise
The Dynamic rise parameter defines the rise in the welding current up to the set dynamic
value at the moment of droplet transfer or in the event of a short-circuit.
Unit
Setting range
Factory settting
0 = Slow rise
10 = Fast rise
54
s
0,1 - 5,0
1,5
Improved ignition, even when using electrodes with poor ignition properties
Better fusion of the base metal in the start-up phase, meaning fewer cold-shut de-
fects
Largely prevents slag inclusions
V
0 - 100
20
-
0 - 10
5