Hotstart Function (Used With Rutile And Cel Processes); Softstart Function (Used With Basic Process); Anti-Stick Function - Fronius TransPocket 2500 Comfort Operating Instructions Manual

Table of Contents

Advertisement

HotStart function
(used with rutile
and Cel process-
I (A)
es)
117A
90A
Example of HotStart function
Mode of operation:
The welding current is raised to a specific value for 1.5 seconds. This value is around 30%
higher than the set welding current
Example: 90 A was set on the adjuster.
The HotStart current is 90 A + 30% = 117 A
IMPORTANT!
If the welding current is set to 192 A or higher, the HotStart current is limited to 250
A.
SoftStart function
The SoftStart function is intended for basic electrodes. Ignition takes place at a low welding
(used with basic
current. Once the arc is stable, the welding current continues to rise until it reaches the
process)
welding current command value.
I (A)
90A
30A
Example of SoftStart function
Anti-stick func-
As the arc becomes shorter, the welding voltage may drop so far that the rod electrode will
tion
tend to stick.
The anti-stick function prevents the electrode from burning out. If the rod electrode begins
to stick, the power source switches the welding current off after 1 second. After the rod
electrode has been lifted off the workpiece, the welding operation can be continued without
difficulty.
1,5 s
t
t
Benefits:
-
Improved ignition properties, even
when using electrodes with poor igniti-
on properties
-
Better fusion of the base material du-
ring the start-up phase, meaning fewer
cold-shut defects
-
Largely prevents slag inclusions
Benefits:
-
Improved ignition properties for elec-
trodes that ignite at low welding cur-
rents
-
Largely prevents slag inclusions
-
Reduces welding spatter
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Transpocket 3500 comfort

Table of Contents