a PIR may still be in lockout, during which it cannot send a signal to complete the
setting process.
Instant Set
The system sets immediately and without any setting tone. The keypad(s) give
confirmation tone when the system is set.
Note: This option does not comply with BS8243:2010.
Silent Set
The system sets after the time programmed in the Entry/Exit Time menu but does not
give any exit tones over the loudspeaker or keypad. When the system sets, the
keypad (but not the loudspeaker) gives a double-beep confirmation tone. (Keypads
give a double-beep tone at the end of all setting modes.)
On entry, both keypads and loudspeakers give entry tones.
Note: This option does not comply with BS8243:2010.
Lock Set
Use this setting if you are using a lock to set the system.
To use Lock Set, you must:
 Configure a Lock Set zone (see page 46) that is activated by a suitable lock
(located on the final exit door).
 Configure a Final Exit zone (see page 43) connected to the final exit door.
Note: It is recommended that you do not use Lock Set within a part set, since the
results may not be predictable.
Setting: Once the user has started the setting sequence, the exit tone sounds, which
continues until the user closes the Final Exit door and operates the lock. When the
Settle Time (page 74) expires, the control unit sets the system and converts the Final
Exit zone in the set partition to a zone of type Normal Alarm.
Unsetting: When a user de-activates the Lock Set zone, the control unit converts
any zone originally programmed as Final Exit back to Final Exit (so that the entry time
starts when the user opens the entry door) and starts a warning tone (distinct from
the entry tone). If the user activates the Lock Set zone again without starting the
Entry Timer, the control unit changes all Final Exit zones back into Normal Alarm
zones and stops the warning tone.
Note: If you use Lock Set, you must set After Entry (page 87) to Never in order to
disable confirmation and comply with BS8243.
Exit Terminate
Setting: The user must start the setting sequence in the normal way, and then
complete setting in one of the following ways once they have left the protected area:
a) By activating an Exit Terminate zone (see page 45).
b) By presenting a proximity reader tag to a KEY-EP external proximity reader
connected to a suitable keypad. This requires System Options – User Access –
Terminated Set to be set to Y (page 84).
When the user starts the setting sequence, the control unit gives the exit tone for the
selected partition(s) and the exit time does not expire. Once the user completes the
setting sequence, the system sets when the Settle Time (page 74) expires.
Unsetting: The user can unset the partition using any of the following methods:
a) By presenting a proximity tag to an external proximity tag reader.
b) By using the Unset button on a remote control.
Settings Options and Partitions Menus
Page 73